Product name : PLC Mask Partical Filtration Efficiency Tester ( PFE ) with PSL Test Aerosol

Test area : 100cm²

Counter sampling flow rate : 2.83L / min ± 5%

Counter laser light source : Laser diode

Screen display : Color 7-inch touch screen

Data export interface : USB

Power supply : AC 220V / 50Hz

Meet Standard : GB 19082, GB / T 32610, YY 0969, ISO-29463

Brand Name : ZL

Model Number : ZL-5066

Certification : CE,ISO

Place of Origin : China

MOQ : 1 set

Price : Negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 60 Sets

Delivery Time : 5-8 work days

Packaging Details : PLC Mask Partical Filtration Efficiency Tester ( PFE ) with PSL Test Aerosol is packaged within wooden case.

Contact Now

PLC Mask Particle Filtration Efficiency Tester (PFE) With PSL Test Aerosol
Product Overview:
The T433S mask filtration efficiency tester is designed for testing filter material efficiency in the range of 45% to 99.9%, following international standards. This compact and lightweight tester requires only suitable power and compressed air (no water, no oil) to operate, making it ideal for laboratory and factory environments.
During filter paper testing, the particle counting method measures counting efficiency using monodisperse aerosol. Pressure drop measurement is performed at specified filtration rates. The filter paper is fixed on the fixture, and test air volume corresponds to required filter speed. Aerosol generated by the aerosol generator is adjusted, electrostatically neutralized (PSL), then uniformly mixed with filtered test air before entering the test area to penetrate the filter material. Resistance measurement and flow rate adjustment are performed manually during testing.
Compliance Standards
  • GB 19082-2009 Technical requirements for medical disposable protective clothing
  • GB 19083-2010 Technical requirements for medical protective masks
  • GB/T 32610-2016 Technical Specifications of Daily Protective Masks
  • GB 2626-2006 Respiratory protective equipment-Self-suction filter anti-particulate respirator
  • YY 0969-2013 Disposable medical masks
  • YY 0469-2011 Medical surgical mask
  • ISO-29463 High-efficiency filters and filter media for removing particulates from the air
Technical Specifications
Parameter Specification
Model ZL-5066
Test efficiency range 45%-99.95%@≥0.3μm
Test area 100cm²
Test pressure range 0-50pa ±1%, 50-500pa ±1.5%
Test flow of the tested filter material 25-100L/min ±2.5% (adjustable)
Test aerosol type PSL
Counter sampling flow rate 2.83L/min ±5%
Particle size display @≥0.3um
Counter laser light source Laser diode
Laser Particle Counter Products comply with JJF1190-2008
Imported air pump Works continuously and stably
Data memory capacity 1-1000 sets of measurement data, exportable
Screen display Color 7-inch touch screen
Printing method Built-in thermal printer
Power supply AC 220V/50Hz
Power 1kw
Data export interface USB
Environment (Operating) 0-40℃ relative humidity 10-70%
Environment (Storage) 0℃-45℃ Relative humidity 0-70%
Dimensions 1000×760×1750 (mm)
Material Shell steel plate paint, test parts SUS304 stainless steel
Weight 150Kg
Warranty 1 year
Standard Accessories
  • Thermal paper
  • Hose (outer diameter 6mm and 15mm)
  • Instruction manual
  • Test report
  • Certificate of conformity
  • PSL aerosol generator
  • Electrostatic neutralizer
  • Diluter
System Components
  • Aerosol Generator: Uses 0.3um PSL standard particles for high-concentration aerosol experiments, with ≥0.3um particles accounting for over 70% of total output
  • Particle Counter: Monitors upstream and downstream particle concentration to calculate filter material efficiency
  • Stainless Steel Fixture: Provides compression and sealing for tested filter materials
  • Differential Pressure Sensor: Measures pressure difference/resistance of filter material under test flow rate
  • Electrical Control & Software: Equipment circuit control, operation, software calculation, data processing, and parameter setting
  • Imported Air Pump: Provides stable test flow through filter material with minimal vibration and noise
PLC Mask Partical Filtration Efficiency Tester ( PFE ) With PSL Test Aerosol

Product Tags:

abrasion resistance testing machine

      

yarn twist tester

      
China PLC Mask Partical Filtration Efficiency Tester ( PFE ) With PSL Test Aerosol wholesale

PLC Mask Partical Filtration Efficiency Tester ( PFE ) With PSL Test Aerosol Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Dongguan Zhongli Instrument Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0